70 HVAC Engineer Interview Questions & Answers (Mechanical)

Q1. What is the Unit of Heat?

BTU (British Thermal Unit) – The amount of heat required to raise the temperature of 1 pound of water by 1°F.

  • 1 lb = 0.45 kg
  • 1 kg = 2.2 lb

Types of Heat:

  • Sensible Heat: Measured by thermometer (e.g. body temperature).
  • Latent Heat: Hidden heat absorbed or released during phase change.

Q2. What is TON of Refrigeration?

TON is the amount of heat required to melt 1 ton of ice in 24 hours.

Q3. Volume of Air is Measured In?

  • CFM – Cubic Feet per Minute
  • CMH – Cubic Meter per Hour
  • m³/sec – Cubic Meter per Second
  • Liters per second

Conversions:

  • CMH = 1.7 × CFM
  • CFM = 2.119 × L/s

Q4. What is ASHRAE?

American Society of Heating, Refrigeration and Air-Conditioning Engineers.

Q5. Standard Room Temperature?

24°C or 76°F

Q6. CFM Formula

CFM = Velocity × Area

Q7. 1 Ton Equals

1 TR = 12,000 BTU/hr = 3.516 kW

Q8. Heat Transfer Coefficient (U)

1 Btu/hr·ft²·°F = 5.6782 W/m²·K

Q9. What is CFM?

Cubic Feet per Minute – unit of airflow.

Q10. Aspect Ratio

Ratio of duct height to width (generally 1:2, max 1:4).

Q11. Collar Length

Strip left at the joint of duct and machine.

Q12. AHU & Chiller Selection Factors

  • CFM
  • Static Pressure
  • Capacity (TR)
  • Air & Water Temperature

Q13. Pump Supply Fittings

  • Thermometer
  • Pressure Gauge
  • Strainer
  • Valve & Flexible Connector

Q14. Pump Return Fittings

  • Eccentric Reducer
  • Check Valve
  • Gate Valve

Q15. CFM Distribution

Use Ductulator.

Q16. Load Calculation Software

HAP 4.32 or equivalent.

Q17. Types of Dampers

  • Fire Damper
  • Smoke Damper
  • Motorized Damper
  • Gravity Damper

Q18. Types of Motorized Dampers

  • Volume Control Damper
  • Fire & Smoke Damper

Q19. Types of Diffusers

1-way, 2-way, 3-way, 4-way, Jet Diffusers.

Q20. What is VFD?

Variable Frequency Drive – used to control motor speed.

Q21. Chilled Water Balancing

Using Double Regulating Valve (DRV).

Q22. Noise Control in Duct

Duct lining (NC-35) and reinforcement.

Q23. Chiller & AHU Water Temperature

  • Chiller Outlet: 6–7°C
  • AHU Inlet: 7–8°C
  • AHU Outlet: 10–11°C
  • Chiller Inlet: 13–15°C

Q24. Primary & Secondary Pumps

Primary: Chiller to building
Secondary: Within building

Q25. FCU & AHU Valve Connection

Refer to AHU installation drawings.

Q26. CFM Value

1 CFM = 0.417 L/s

Q27. Refrigerants Used

R22, R12, R134a (depends on system).

Q28. Duct Heaters

Used for heating in specific areas.

Q29. What is VAV?

Variable Air Volume system used to control airflow and temperature.

Q30. 2-Way & 3-Way Valve

  • 2-Way: Regulates flow
  • 3-Way: Bypass during minimum load

Q31. Duct Gauge

Supply: 22G | Exhaust: 18G

Q32. Types of Duct Joints

Slip joint, Flange joint.

Q33. HVAC Standard Books

ASHRAE & SMACNA

Q34. Smoke & Light Test

Used for duct leakage testing.

Q35. Duct Sizing Methods

  • Equal Friction
  • Velocity Method
  • Static Regain

Q36. Noise Measurement

Measured using dB meter.

Q37. Pressure Drop in Chilled Water Pipes

210 Pascal/meter

Q38. Fire, Splitter & NR Dampers

Used for fire safety, air balancing, and preventing backflow.

Q39. Exhaust Fans

Axial, Centrifugal, Twin fans.

Q40. Duct Shapes

Rectangular, Round, Spiral, Oval.

Q41. Vibration Control

Spring isolators, rubber pads, flexible bellows.

Q42. VAV vs CAV

Variable Air Volume vs Constant Air Volume.

Q43. Chiller Valve Arrangement

Standard HVAC valve layout.

Q44. Plant Room Layout Considerations

Space, orientation, unit type.

Q45. Types of Louvers

Fresh air, sand trap, acoustic, back draft.

Q46. Types of Chillers

Air-cooled & Water-cooled (Reciprocating, Screw, Centrifugal).

Q47. Chilled Water Pipe Test Pressure

1.5 times working pressure.

Q48. Chiller Safety Devices

Flow switch, HP cut-out, oil pressure switch.

Q49. Human Comfort Conditions

22 ±2°C & 50% RH

Q50. Temperature Where °C = °F

-40°C

Q51. Gas Used for Brazing

Nitrogen

Q52. 1 TR Equals

365–400 CFM, 3.516 kW

Q53. Main Duct Velocity

900–1100 FPM

Q54. Duct Insulation

Inside: 25 mm | Outside: 50 mm

Q55. Nominal vs Actual Capacity

Depends on operating conditions.

Q56. Nominal Capacity Same Worldwide?

Yes.

Q57. Weight of Duct

Wt = 8.0318 × Thickness × Perimeter

Q58. Underground Chilled Water Pipe Material

Pre-insulated black steel pipe (Sch-40).

Q59. Velocity Calculation

Using GPM, friction & ASHRAE charts.

Q60. What is FCU?

Fan Coil Unit used for cooling/heating.

Q61. Function of AHU

Condition and circulate air.

Q62. Types of AC Systems

Window, Split, Packaged, Central AC.

Q63. What Does an HVAC Engineer Do?

Design, installation, maintenance of HVAC systems.

Q64. What is HVAC?

Heating, Ventilation & Air Conditioning.

Q65. Meaning of BTU

Heat required to raise 1 lb water by 1°F.

Q66. Variable Air Volume System

Controls airflow at constant temperature.

Q67. Constant Air Volume System

Constant airflow, variable temperature.

Q68. Centralized Air System

Central cooling using condenser and evaporator.

Q69. What is FAHU?

Fresh Air Handling Unit.

Q70. CFM & Infiltration

Outside air entering a building measured in CFM.